A safety test that passed is worth what the record says.
Electrical product testing carries a BIS licence behind it. ErgoLIMS holds the IS and IEC methods, evaluates against the conductor and insulation limits on entry, and keeps the licence number on every sample it applies to.
Bolts crossing — drawn live in the browser, no two frames alike
The licence is on the line, and the evidence is in a folder
Conductor resistance limits vary by cross-section and temperature. Insulation resistance is checked against a table. The BIS licence number the sample was tested under sits on a covering letter, not the record. When BIS asks for evidence of routine testing, assembling it is a week of work.
Six things a electrical lab gets that a spreadsheet cannot give it
Each of these is a shipped capability, not a roadmap item.
Conductor and insulation limits evaluated on entry
Volume resistivity, conductor resistance at 20 °C for 1.5 mm² and 2.5 mm², high-voltage withstand and insulation resistance limits arrive pre-loaded from IS 694 and IS 8130. A breach flags as the value is entered.
The BIS licence travels with the sample
Batch, BIS licence number, voltage rating and grade or type are structured registration fields on every sample — searchable, printable and permanent.
HV sets that lapse cannot certify
HV test sets, insulation resistance testers, micro-ohmmeters and oil BDV kits carry calibration and maintenance schedules with certificates attached. A lapsed calibration locks the instrument out of result entry.
High voltage work needs a cleared operator
Per-method authorisations carry competency level and expiry. An operator not signed off for dielectric testing cannot report against that method — refused on the server, not hidden in the interface.
Temperature-corrected resistance, computed
Analysts enter measured resistance and temperature; the server evaluates the correction to 20 °C with your rounding rules and writes an immutable execution log.
Certificates a purchaser can verify
Reports carry a NABL ULR allocated atomically and a public QR code anyone can scan without logging in. A revoked report returns a hard error rather than continuing to look valid.
How a electrical sample moves through the system

The registration form — three steps, with the customer-committed date and the internal lab target kept as separate fields.
Three people in the lab, three different wins
Enter the measured resistance and temperature; the correction, the limit check and the record are the system's job.
Every result tested under a BIS licence is one query, and every failure carries a documented investigation.
Verify a safety certificate by QR without calling the lab, and track jobs through the portal.
Compliance a electrical assessor will recognise
IS 694 · IS 8130 · IS 335 · IS 2026
Cable, conductor, transformer oil and transformer loss methods with their published references, plus five pre-loaded limits.
IEC 60228 · 60335 · 60947 · 60811
Conductor resistance, appliance safety, switchgear temperature rise and cable insulation methods seeded as editable templates.
NABL · ISO/IEC 17025:2017
ULR numbering, authorised signatories, method validation, measurement uncertainty and a full quality management system.
And you do not start from an empty system
Choose the electrical domain at setup and ErgoLIMS provisions the scaffolding for you — as editable templates, not a locked configuration. Limits shown arrive pre-loaded. They are editable, versioned and can be overridden per customer or per product.
Questions we hear from electrical labs
See it run on your own parameters
A 30-minute walkthrough with the engineers who built it — using your methods, your limits and your reporting format, not a canned script.